Oxygen Index Test Apparatus
Structure
and Principle for Oxygen Index Test Apparatus
Date: May 16th, 2016 Author: QINSUN
Oxygen
Index Test Apparatus Structure Introduction:
Oxygen Index Test Apparatus is made by the combustion tube, specimen holder,
flow control system and ignition components.
Combustion
tube is a heat-resistant glass, the lower end of the tube inserted in the base,
a certain height within the base filled with glass beads, metal mesh is placed
on a glass beads, for blocking burning droplets. The specimen is clamped a
metal spring, the film material, use a U-shaped sample holder. Flow control
system consists of pressure gauge, regulator valve, control valve, rotameter
and piping components. Igniter flame length is adjustable, the test flame
length of 10mm.
Oxygen Index Test Apparatus Standard:
According to "EN ISO 4589-2: 2006-06 room temperature oxygen index
test" and "GBT 2406-1993 Test method for flammability of plastic
oxygen index" "GBT 8924-2005 fiber reinforced plastics burning
behavior by oxygen index of production requirements.
Oxygen Index Test Apparatus Technical
Reference:
1,
measuring range: 0-100% / 02.
2,
resolution: 0.1% / 02.
3,
the measurement accuracy: (± 0.4%), / 02.
4,
Response time: <l0s.
5,
digital precision: 0.1% ± 1 word.
6,
the output drift: <5% / year.
7,
stopwatch: accuracy 0.5s.
8,
Dimensions approximately: 360mm × 250mm × 530mm.
9,
Warranty: 12 months after delivery.
Oxygen Index Test Apparatus working
conditions:
1, Environment temperature: -10 ℃ -40 ℃.
2,
relative humidity: ≤85%.
3,
the use of gas: GB3863 industrial gaseous oxygen; GB3864 industrial gaseous
nitrogen; two bottles of gas have to be the regulator (with user).
4,
input pressure: (0.25-0.4) Mpa.
5,
Working pressure: 0.l Mpa.
Oxygen Index Test Apparatus Description:
Product Name: Digital Oxygen index tester also known
as: oxygen index analyzer, made by Qinsun Instruments Co., LTD., Model:
XWR-2406 (product model using "JBT 10059-1999 tester and nondestructive
testing model designation is defined)
Reference
standard:
GB / T 2406-1993 “ Plastics. Determination of burning behavior
by oxygen index"
(Limiting) Oxygen Index Test Apparatus Product principle and function:
Clearly define the oxygen index and its application in
the principle of relative combustibility evaluation of polymer materials
Understand
the structure and working principle of the oxygen index apparatus
Master with oxygen index tester and the basic methods of oxygen index
determination of common materials
To evaluate the combustion performance of common materials.
Material is burned, need to consume large amounts of oxygen, different fuel,
burning need to consume the amount of oxygen, through to the material in the
process of burning the determination of minimum oxygen consumption, calculate
the material of the oxygen index value, to evaluate the combustion performance
of matter. So-called Oxygen index (Oxygen index), refers to the regulation of
test conditions, specimen in Oxygen and nitrogen mixture flow, to maintain
stable combustion (i.e., to meet the need of flaming), minimum Oxygen
concentration in Oxygen volume percentage of the value (i.e. in the material
after ignition, burning time can keep burning 50 mm long or 3 min need Oxygen,
nitrogen, minimum volume percentage of Oxygen concentration in the mixed gases).
It is as material in contact with the flame in the air when the ease of burning
is very effective. It is generally believed that OI < 27 belong to flammable
materials, 27 OI or less < 32 is a combustible material, OI of 32 or flame
retardant material. HC - type 2 oxygen index tester, is used to determine the
volume percentage of oxygen required material combustion process.
Oxygen index test method, is to a certain size of the sample with the sample
holder vertical clamping in the transparent combustion cylinder, there are
mixed in a certain proportion of upward mobility oxygen nitrogen flow. Is
burning with the top of the sample, observing the subsequent combustion
phenomenon, and record the combustion duration or burned distance, burning time
of sample more than 3 min or flame front line more than 50 mm, lower oxygen
concentrations, the burning time of sample can't less than 3 min or flame front
lines, will increase the oxygen concentration, so repeatedly, from the top and
bottom sides gradually close to the specified value, to the concentration
difference of the two is less than 0.5%. < / l0s.
You
can follow as below, Qinsun
Instruments Co., LTD, Address:
No. 258 Banting Road, Shanghai, Zip
Code: 201199
Phone:
+86-21-6420 0566 Fax: +86-21-6420
0566-810 E-mail: info@qinsun-lab.com website: www.qinsun-lab.com.
Oxygen Index Test Apparatus is made by the combustion tube, specimen holder, flow control system and ignition components.
Oxygen Index Test Apparatus Standard:
According to "EN ISO 4589-2: 2006-06 room temperature oxygen index test" and "GBT 2406-1993 Test method for flammability of plastic oxygen index" "GBT 8924-2005 fiber reinforced plastics burning behavior by oxygen index of production requirements.
Oxygen Index Test Apparatus Technical Reference:
Oxygen Index Test Apparatus working conditions:
1, Environment temperature: -10 ℃ -40 ℃.
Oxygen Index Test Apparatus Description:
Product Name: Digital Oxygen index tester also known as: oxygen index analyzer, made by Qinsun Instruments Co., LTD., Model: XWR-2406 (product model using "JBT 10059-1999 tester and nondestructive testing model designation is defined)
Reference standard:
GB / T 2406-1993 “ Plastics. Determination of burning behavior by oxygen index"
Clearly define the oxygen index and its application in the principle of relative combustibility evaluation of polymer materials
Master with oxygen index tester and the basic methods of oxygen index determination of common materials
To evaluate the combustion performance of common materials.
Material is burned, need to consume large amounts of oxygen, different fuel, burning need to consume the amount of oxygen, through to the material in the process of burning the determination of minimum oxygen consumption, calculate the material of the oxygen index value, to evaluate the combustion performance of matter. So-called Oxygen index (Oxygen index), refers to the regulation of test conditions, specimen in Oxygen and nitrogen mixture flow, to maintain stable combustion (i.e., to meet the need of flaming), minimum Oxygen concentration in Oxygen volume percentage of the value (i.e. in the material after ignition, burning time can keep burning 50 mm long or 3 min need Oxygen, nitrogen, minimum volume percentage of Oxygen concentration in the mixed gases). It is as material in contact with the flame in the air when the ease of burning is very effective. It is generally believed that OI < 27 belong to flammable materials, 27 OI or less < 32 is a combustible material, OI of 32 or flame retardant material. HC - type 2 oxygen index tester, is used to determine the volume percentage of oxygen required material combustion process.
Oxygen index test method, is to a certain size of the sample with the sample holder vertical clamping in the transparent combustion cylinder, there are mixed in a certain proportion of upward mobility oxygen nitrogen flow. Is burning with the top of the sample, observing the subsequent combustion phenomenon, and record the combustion duration or burned distance, burning time of sample more than 3 min or flame front line more than 50 mm, lower oxygen concentrations, the burning time of sample can't less than 3 min or flame front lines, will increase the oxygen concentration, so repeatedly, from the top and bottom sides gradually close to the specified value, to the concentration difference of the two is less than 0.5%. < / l0s.